Official Bank 0/159

Check Point Certified Security Master – R80 Exam (156-115.80) - Checkpoint Exam Questions

Last updated on June 22, 2026

97% Exam Compliance
159 Total Questions
1
Question
The customer is using Check Point appliances that were configured long ago by third-party administrators. Current policy includes different enabled IPS protections and Bypass Under Load function. Bypass Under Load is configured to disable IPS inspections if CPU and Memory usage is
higher than 80%. The Customer reports that IPS protections are not working at all regardless of CPU
and Memory usage. What is a possible reason of such behavior?
Options
A The kernel parameter ids_assume_stress is set to 1
B The kernel parameter ids_assume_stress is set to 0
C The kernel parameter ids_tolerance_stress is set to 10
D The kernel parameter ids_tolerance_no_stress is set to 10
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question
The fw monitor output file type is?
Options
A tar.gzip
B Binary
C ASCII text
D ZIP
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question
Consider a Check Point Security Gateway under high load. What mechanism can be used to confirm that important traffic such as control connections are not dropped?
Options
A fw ctl debug –m fg all
B fw ctl multik prioq
C fw debug fgd50 on OPSEC_DEBUG_LEVEL=3
D fgate –d load
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question
Having a look at the output of the “fwaccel conns” command, the F flag is the indicator for a packet .
Options
A being processed by the firewall kernel module
B being forced of using the accelerated path
C getting the routing information according to the Forwarding Information Base (FIB)
D going through the slow path
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question
The clusterXL_monitor_ips script .
Options
A registers the admin_down device and checks the change in the member’s status and provides feedback to the user.
B registers the host_monitor device and checks end-to-end connectivity to routes and other network devices.
C registers devices with the name of a process specified in the cpha_proc_list file.
D registers devices that monitor the IPS blade.
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

Finish Practice?

Are you sure you want to finish? This will end your practice session.