Official Bank 0/60

PowerEdge Specialist Exam for Implementation Engineer (DES-4121) - EMC Exam Questions

Last updated on June 20, 2026

97% Exam Compliance
60 Total Questions
1
Question
Refer to the exhibit.

Exhibit

A technician tries to apply s BIOS update on a sever through the iDRAC wed interface using the Linux Dell Update Package filo BIOS _2M4CC_LN_2 0 2 BIN. This results in the error shown in the exhibit. What should the technician do to address this issue?
Options
A Download and apply the Windows Dell Update Package tile
B Extract the Linux Dell Update Package and apply payload file
C Reset the iDRAC and reply the update
D Re-download the file to replace the corrupted version and reinstall
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question
A technician is installing a new server and is not getting any link lights on the iDRAC management port. They have verified that the cable and switch port are working.

What could be causing this issue?
Options
A iDRAC firmware update is currently in progress
B IP has not boon set the Lifecycle Controller
C iDRAC has an Express license
D iDRAC has been disabled in the lifecycle Controller
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question
A server has two power supply unites (PSUs) m a redundant configuration. One PSU fails. A technician replaces the failed PSU, but the server does not return to redundant power mode.

What is the cause of this issue?
Options
A Now PSU has a different wattage than the existing PSU
B Server has not been power cycled to bring the now PSU online
C Power redundant option is disabled in the System Setup Utility
D Both PSUs were not replaced at the same lime
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question
A technician is change me iDRAC IP address from, the static IP address 10 37 125 88 to DHCP on the technician PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine IP address was given to me iDRAC and they cannot reboot the server.

What method could the technician use to determine what IP address is assigned to the iDRAC?
Options
A Hold the system identification button down for more than 3 seconds to reset it back to the default static address 192 168.0 120
B Plug a monitor or KVM into the system Reboot the server to view the assigned IP iDRAC address on the Dell boot up splash screen
C Use the iDRAC direct feature. Access iDRAC web GUI and determine the assigned IP address.
D log n lo the lifecycle and check the ORAC Settings
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question
A technician needs to add a device to SupportAssisI Enterprise Policy requires that no additional software be installed on the server OS. In addition to Username and Password, what information is required to add the device?
Options
A IP address or hostname tor the iDRAC
B IP address for Dell TechDirect
C IP address for OpenManage Server Administrator
D IP address or hostname for the server OS
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

Finish Practice?

Are you sure you want to finish? This will end your practice session.