Official Bank 0/59

Integrating HPE Synergy Solutions (HPE0-S50) - HP Exam Questions

Last updated on June 20, 2026

97% Exam Compliance
59 Total Questions
1
Question
Which utility compares currently running firmware with the upgrade firmware for the HPe Synergy FB Switch Module.

Which allows minimal downtime during the aggrade?
Options
A ISSU
B SMU
C VCSU
D SUM
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question
Refer to the exhibit.

Exhibit

How should a Synergy integrator pair interconnect bays to set up redundant fabrics in an HPE Synergy 12000 Frame?
Options
A Interconnect bays 1 and bays 2: bays 3 and 4: bays 5 and 6.
B Interconnect bays 1 and 3: bays 2 and 4: bays 5 and 6.
C Interconnect bays 1 and 1 and 6: bays 2 and 5: bays 3 and 4.
D Interconnect 1 bays 1 and 4: bays 2 and 5: bays 3 and 6.
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question
A Synergy integrator is expanding a customer’s HPE Synergy solution. The existing solution includes:

* two HPE Synergy 12000 Frames

* two HPE Virtual Connect SE 40GB F8 modules.

* two HPE Synergy 20Gb interconnect Link Modules.

*highly available management ring with two Synergy Composers.

The integrator plans to add:

* two new HPE synergy 12000 Frames

* two HPE Virtual Connect SE 40GB F8 modules

* two HPE Synergy 20Gb interconnect Link Modules

*redundant Frame Link Modules in each new frame

Which additional components are necessary for successful implementation?
Options
A two CAT6A cables, four 120Gb Interconnect Link Module cables, and two 40Gb QSFP+ to QSFP+ direct attach cables.
direct attach cables.
B four CAT6A cables, eight 120Gb Interconnect Link Module cables, and four 40Gb QSFP+ to QSFP+
C four CAT6A cables, four 120Gb Interconnect Link Module cables, and two 40Gb QSFP+ to QSFP+ direct attach cables.
direct attach cables.
D two CAT6A cables, four 120Gb Interconnect Link Module cables, and one 40Gb QSFP+ to QSFP+
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question
A customer has the following requirements for an HPE Synergy solution:

* Data for the internal application needs to be stored in the frame.

* Compute modules needs to have access to a large database on an external storage array.

* The Synergy infrastructure should be managed with HPE OneView
Options
A Two SAS Connection Modules into 1 and 2: two Synergy 40Gb Fb switch module into bays 3 and 4 two Brocade 16Gb/12 Fiber Channel switches into bays 5 and 6
B two SAS Connection Modules into bays 1 and 4: 4 two Synergy 40Gb F8 switch modules into 2 and
5: two Brocade 16Gb/12 FC Switches into bays 3 and 6
C two SAS Connection Modules into bays 1 and 2: two HPE Synergy Connect SE 40Gb F8 modules into bays and 4
D two SAS Connection Modules into bays 1 and 4, two HPE Synergy Connect SE modules into bays 3 and 6
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question
A synergy integration creating a network that must be connected from the Synergy Connect SE 40Gb FB module to an Ethernet switch carrying 500 VLANs for the hypervisor cluster.

Which network should the synergy integrator select during network creation?
Options
A Ethernet Tunneled
B Ethernet Untagged
C Ethernet Tagged
D Ethernet Channel
Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

Finish Practice?

Are you sure you want to finish? This will end your practice session.