Official Bank 0/73

Specialist - Implementation Engineer, VMAX All Flash and VMAX3 Solutions (E20-807) - EMC Actual Exam Questions

Last updated on April 25, 2026

97% Exam Compliance
73 Total Questions
1
Question

A new VMAX3 array has been added to the environment. Unisphere for VMAX has discovered the array and can be used to manage the array. However, Unisphere is not able to collect any performance data for the array. What is a possible cause?

Options
A

Registration for performance data collection has not been done

B

Performance data repository is full

C

storgnsd daemon is not running

D

Root Cause Analysis Interval was changed

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question

Alerts are required to track high I/O response times for a specific storage group. I/O response times greater than 15 ms require next day analysis. I/O response times greater than 20 ms require immediate intervention. Which alert settings are required?

Options
A

1st level – Informational, 15 ms, e-mail2nd level – Warning, 20 ms, Syslog

B

1st level – Warning, 15 ms, syslog2nd level – Critical, 20 ms, SNMP trap

C

1st level – Warning, 14 ms, SNMP trap2nd level – Critical, 19 ms, SNMP trap

D

1st level – Warning, 16 ms, e-mail2nd level – Critical, 21 ms, Syslog

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question

A VDI deployment is planned for an environment that consists of VMAX3 and XtremIO. The data will have a high degree of deduplication and will require QoS and VVOL support. How can the existing infrastructure be leverage while minimizing increased storage capacity?

Options
A

Use XtremIO for the new deployment

B

Use FAST.X with XtremIO for the new deployment

C

Add full capacity required for VMAX3

D

Add half the capacity required for the VMAX and use compression

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question

An organization plans to implement a VMAX3 solution using a two tier configuration. They are sensitive to data loss. the array will include: 10 x Flash drives 144 x 10k drives Based on Dell EMC recommended best practices, how should the Flash drives be configured?

Options
A

1 group RAID 6 (14+2)

B

2 groups RAID 6 (6+2)

C

2 groups RAID 5 (7+1)

D

4 groups RAID 5 (3+1)

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question

If an XtremIO external tier is placed in its own Storage Resource Pool, which SLO is associated with the external tier?

Options
A

Platinum

B

Silver

C

Gold

D

Optimized

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

Finish Practice?