Official Bank 0/136

VMAX3 Solutions and Design Specialist Exam for Technology Architects (E20-542) - EMC Actual Exam Questions

Last updated on April 23, 2026

97% Exam Compliance
136 Total Questions
1
Question

A company has two VMAX3 arrays installed at two different sites. VMAX3 eNAS is configured on both arrays with IP network connectivity between them. The company wants to make multiple copies of their file system volumes while using minimal additional space. Which EMC technology meets this requirement without additional hardware?

Options
A

SnapSure

B

TimeFinder

C

SRDF

D

Replicator

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question

A VMAX3 parent Storage Group (SG) contains two child SGs: SG1 and SG2. What is a valid Host I/O bandwidth limit setting for this configuration?

Options
A

Parent SG - 400 SG1 - 500, SG2 - 200

B

Parent SG – 400 SG1 - 500, SG2 - NOLIMIT

C

Parent SG – 500 SG1 - 500, SG2 - 400

D

Parent SG – 500 SG1 - NOLIMIT, SG2 - 1000

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question

Based on best practice, when is a three-tier configuration recommended for a VMAX3?

Options
A

Low skew workload

B

Low write workload

C

High skew workload

D

High read workload

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question

A VMAX3 customer has linked a TimeFinder SnapVX snapshot to a target in Copy mode. The copy has completed. Which operation will disassociate the linked target and provide a full usable copy?

Options
A

Unlink

B

Split

C

Relink

D

Establish

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question

A storage administrator began taking nightly TimeFinder SnapVX snapshots of Oracle database LUNs 7 days ago. The administrator reports that the snapshots failed the previous night. What advice should be provided to the administrator?

Options
A

Confirm there is available capacity in the Storage Resource Pool

B

Update the Solutions Enabler database and re-run the snapshots

C

Confirm the database was put in hot backup mode before the snapshot

D

Link the last good snapshot to a target and restore the database LUNs

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

Finish Practice?