Refer to the exhibit. The FCoE traffic fails to traverse the vfc2 interface. The VSAN 102 is configured for vfc2. Which action resolves the issue?
Enable LLDP on the interface vfc2
Activate DCBX on the N9K switch
Activate DCBX on the interface e101/1/2
Enable LLDP on the neighbor switch
to join the discussion
No discussions yet. Be the first to ask!
Delete Comment
Are you sure? This action cannot be undone.
Refer to the exhibit. An attempt to bind the Ethernet interface to vFC fails. Which action resolves the issue?
Add the FCoE VLAN to the allowed VLAN list.
Configure the FCoE VLAN that corresponds to the vFC VSAN as a private VLAN.
Configure the interface as a trunk port.
Configure the interface to use the native VLAN of the trunk port.
to join the discussion
No discussions yet. Be the first to ask!
Delete Comment
Are you sure? This action cannot be undone.
Refer to the exhibit. A network engineer upgrades the firmware of a Cisco Fabric Interconnect from boot flash. During the process, the fabric interconnect reboots and displays the message shown in the exhibit. Which action resolves the issue?
Remove the service pack and upgrade through the auto-install procedure
Reset the I/O module and install the firmware image from the boot flash
Boot the kickstart image from boot flash and load the system image
Reload the switch and boot the kickstart image from the TFTP server
to join the discussion
No discussions yet. Be the first to ask!
Delete Comment
Are you sure? This action cannot be undone.
A system administrator connects a Cisco Nexus 2248PQ FEX to a fabric interconnect to expand the ports that are available for connecting Cisco UCS C-Series Rack Servers. In Cisco UCS Manager, the administrator does not see the servers connected to this FEX. Which action should be taken to resolve the issue?
The FEX must be exchanged so that it supports the connectivity between fabric interconnects and UCS CSeries servers
The fabric interconnects must be rebooted before the FEX is recognized
The transceivers must be exchanged to support the connectivity between the FEX and the fabric interconnects
The ports that connect the FEX to the fabric interconnects must be configured as server ports
to join the discussion
No discussions yet. Be the first to ask!
Delete Comment
Are you sure? This action cannot be undone.
An engineer upgrades Cisco UCS firmware from release 3. 1(2) to release 3. 1(3) using Autolnstall. Both fabric interconnects go ofline during the software upgrade installation and issue multiple F SM retries in the DeployPollActivate stage. Which set of actions resolves the issue?
Fix the rights to 666 with the debug plugin on the primary fabric interconnet Save the current configuration on the running fabric interconnect. Continue the upgrade on both fabric interconnects.
Enable the management interface monitoring policy on the fabric interconnects. Initiate a configuration backup on both fabric interconnects. Commit the pending fabric interconnect reboot activity.
Acknowledge the error and reboot the primary fabric interconnect. Clear the default firmware version and upload a new one. Restart the upgrade process manually.
Clear the startup version of the default infrastructure and server pack. Remove the service pack from the subordinate node. Upgrade with the Force attribute through Autolnstall.