1
Question

Refer to the exhibit. The FCoE traffic fails to traverse the vfc2 interface. The VSAN 102 is configured for vfc2. Which action resolves the issue?

Question image
Options
A

Enable LLDP on the interface vfc2

B

Activate DCBX on the N9K switch

C

Activate DCBX on the interface e101/1/2

D

Enable LLDP on the neighbor switch

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

2
Question

Refer to the exhibit. An attempt to bind the Ethernet interface to vFC fails. Which action resolves the issue?

Question image
Options
A

Add the FCoE VLAN to the allowed VLAN list.

B

Configure the FCoE VLAN that corresponds to the vFC VSAN as a private VLAN.

C

Configure the interface as a trunk port.

D

Configure the interface to use the native VLAN of the trunk port.

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

3
Question

Refer to the exhibit. A network engineer upgrades the firmware of a Cisco Fabric Interconnect from boot flash. During the process, the fabric interconnect reboots and displays the message shown in the exhibit. Which action resolves the issue?

Question image
Options
A

Remove the service pack and upgrade through the auto-install procedure

B

Reset the I/O module and install the firmware image from the boot flash

C

Boot the kickstart image from boot flash and load the system image

D

Reload the switch and boot the kickstart image from the TFTP server

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

4
Question

A system administrator connects a Cisco Nexus 2248PQ FEX to a fabric interconnect to expand the ports that are available for connecting Cisco UCS C-Series Rack Servers. In Cisco UCS Manager, the administrator does not see the servers connected to this FEX. Which action should be taken to resolve the issue?

Options
A

The FEX must be exchanged so that it supports the connectivity between fabric interconnects and UCS CSeries servers

B

The fabric interconnects must be rebooted before the FEX is recognized

C

The transceivers must be exchanged to support the connectivity between the FEX and the fabric interconnects

D

The ports that connect the FEX to the fabric interconnects must be configured as server ports

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!

5
Question

An engineer upgrades Cisco UCS firmware from release 3. 1(2) to release 3. 1(3) using Autolnstall. Both fabric interconnects go ofline during the software upgrade installation and issue multiple F SM retries in the DeployPollActivate stage. Which set of actions resolves the issue?

Options
A

Fix the rights to 666 with the debug plugin on the primary fabric interconnet Save the current configuration on the running fabric interconnect. Continue the upgrade on both fabric interconnects.

B

Enable the management interface monitoring policy on the fabric interconnects. Initiate a configuration backup on both fabric interconnects. Commit the pending fabric interconnect reboot activity.

C

Acknowledge the error and reboot the primary fabric interconnect. Clear the default firmware version and upload a new one. Restart the upgrade process manually.

D

Clear the startup version of the default infrastructure and server pack. Remove the service pack from the subordinate node. Upgrade with the Force attribute through Autolnstall.

Discussion (0 comments)

to join the discussion

Community Discussion

No discussions yet. Be the first to ask!